MICHAELKORSPASCHER.FR ≡ Solo Watches Digital Ossilloscope Love & Marriage
  • Digital Ossilloscope Multimeter

  • Hantek DSO8202E 200Mhz Handheld Digital Oscilloscope

Hantek DSO8202E 200Mhz Handheld Digital Oscilloscope

$17.31 $21.46
Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform generator. IP-51 rated for dust, drip and shake proof to withstand harsh environments. Large fuse confirms to European Safety Standard. Battery indicator with easy-changed connect points. Selectable 18650 battery box for matching 18650 battery by yourself. Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness. Replaceable BNC safety joints, and additional one set of joints. 1GSa/s sample rate, 2M Memory depth, 6000 counts DMM. Large 5.6 inch TFT Color LCD Display; High Resolution(640*480) Model DSO8072E DSO8102E DSO8152E DSO8202E Acquisition Sample Modes Real-Time Sample Acquisition Modes   Normal Normal data only Peak Detect High-frequency and randon glith capture Average Wavefom Average, selectable 4,8,16,32,64,128 Inputs Inputs Coupling AC, DC, GND Inputs Impendance 1MΩ±2% ‖20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×) Horizontal System Sample Rate Range 1GS/s Waveform Interpolation (sin x)/x Record Length 2M SEC/DIV Range 4ns/div~2000s/div, in a  2, 4, 8 sequence 2ns/div~2000s/div, in a  2, 4, 8 sequence Sample Rate andDelay Time Accuracy ±50ppm over any ≥1ms time interval Scanning Speed Range 4ns/div to 8ns/div; (-8div x s/div) to 40ms;20ns/div to 80μs/div;(-8div×s/div) to 40ms;200μs/div to 40s/div;(-8div×s/div) to 400s; 2ns/div to10ns/div;(-4div×s/div) to 20ms; Delta Time Measurement Accuracy(Full Bandwidth) Single-shot, Normal mode:± (1 sample interval 100ppm × reading 0.6ns);>16 averages:± (1 sample interval 100ppm × reading 0.4ns);Sample interval = s/div ÷ 200 Vertical System Vertical Resolution 8-bit resolution, all channel sampled simultaneously Volts Range 2mV/div to 100V/div at input BNC Bandwidth 70MHz 100MHz 150MHz 200MHz Rise Time at BNC( typical) 5ns 3.5ns 2.3ns 1.8ns Analog Bandwidth inNormal and Averagemodes at BNC or with probe,DC Coupled ±400V(100V/div-20V/div); ±50V(10V/div-5V/div);±40V(2V/div-500mV/div);±2V(200mV/div-50mV/div);±400mV(20mV/div-2mV/div); Math , -, *, /, FFT FFT Windows:  Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) ≤10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 100V/div to 10mV/div.±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div. DC Measurement Accuracy,Average Acquisition Mode Measurement Type: Average of ≥16 waveforms with vertical position at zeroAccuracy: ± (3% × reading 0.1div 1mV) when 10mV/div or greater is selected.Measurement Type: Average of ≥16 waveforms with vertical position not at zeroAccuracy: ± [3% × (reading vertical position) 1% of vertical position 0.2div]. Volts Measurement Repeatability,Average Acquisition Mode Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, AC Line Trigger Modes Auto, Normal, Single Coupling Type DC, AC, HF Reject, LF Reject, Noise Reject Trigger Sensitivity(Edge Trigger Type) DC(CH1,CH2):1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;AC: Attenuates signals below 10Hz ;HF Reject: Attenuates signals above 80kHz;LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz.   Trigger Level Range CH1/CH2: ±8 divisions from center of screen;  Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; Set Level to 50%(typical) Operates with input signals ≥50Hz Video Trigger   Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions; Signal Formats and Field Rates Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger   Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.Less than: The trigger point is the trailing edge.Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger   Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.Less than: The oscilloscope triggers when the waveform slope is less than the set slope.Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. Time Range 20ns ~ 10s Overtime Trigger   Over Time Modee Rising edge or Falling edge Time Range 20ns ~ 10s Alternative Trigger   Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope Trigger Frequency Counter   Readout Resolution 6 digits Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors) Frequency Range AC coupled, from 4Hz minimum to rated bandwidth Signal Source Pulse Width or Edge Trigger modes: all available trigger sourcesThe Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.Video Trigger mode: The Frequency Counter does not work. Measure Cursor Measurement Manual: Voltage difference between cursors: △V             Time difference between cursors: △T             Reciprocal of △T in Hertz (1/ΔT);Tracing: The valtage and time at a waveform point; Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, Waveform Generator Mode Frenquency Range 1Hz(DC)~25MHz DAC Clock 2K~200MHz adjustable Memory Depth 4KSa Vertical Resolution 12 Bits Stability <30ppm Amplitude ±3.5V Max. Output Impedance 50 Ω Output Current 50mA Ipeak=50mA System Bandwidth 25M Harmonic Wave Distortion  -50dBc(1KHz),  -40dBc(10KHz) General Specifications Display Resolution 640 horizontal by 480 vertical pixels Display Contrast Adjustable (16 gears) with the progress bar Probe Compensator Output   Output Voltage( typical) About 2Vpp into ≥1MΩ load Frequency(typical) 1kHz Power Supply   Supply Voltage AC Input:100-240VACRMS,0.6A MAX,50Hz~60Hz; DC Output:9V,2A Power Consumption <30W Environmental   Temperature Operating: 32℉ to 122℉ (0℃ to 50℃);Nonoperating: -40℉ to 159.8℉ (-40℃ to 71℃) Cooling Method Convection Humidity 104℉ or below ( 40℃ or below): ≤90% relative humidity;106℉ to 122℉ ( 41℃ to 50℃): ≤60% relative humidity Altitude Operating: Below 3,000m (10,000 feet);Nonoperaring: Below 15,000m(50,000 feet) Mechanical   Size 260mmmm; 220mm; 75mm Weight 2.5KG(without Packing) DMM Mode Max. Resolution 6000 Counts DMM Testing Modes Voltage, Current, Resistance, Capacitance, Diode & Continuity Max. Input Voltage AC:600V, DC: 800V Max. Input Current AC: 10A, DC:10A Input Impedance 10MΩ DMM TrendPlot 1.2M  Point Range Resolution Accuracy Resolution DC Voltage 60.00mV ±1%±3 digit 10uV 600.0mV 100uV 6.000V 1mV 60.00V 10mV 600.0V 100mV 800V 1V AC Voltage 60.00mV ±1%±3 digit 10uV 600.0mV 100uV 6.000V 1mV 60.00V 10mV 600.0V 100mV DC Current 60.00mA ±1%±5 digit 10uA 600.0mA ±1.5%±5 digit 100uA 6.000A 1mA 10.00A 10mA AC Current 60.00mA ±1%±5 digit 10uA 600.0mA ±1.5%±5 digit 100uA 6.000A 1mA 10.00A 10mA Resistance 600Ω ±1%±3 digit 0.1Ω 6.000KΩ 1Ω 60.00KΩ 10Ω 600.0KΩ 1KΩ 6.000MΩ 10KΩ 60.00MΩ ±1%±5 digit 100KΩ Capacitance 40.00nF ±2%±5 digit 10pF 400.0nF 100pF 4.000uF 1nF 40.00uF 10nF 400.0uF 100nF Attention: the smallest capacitance value that can be measured in 5nF Diode 0V~2.0V ON-OFF test <10Ω   Model DSO8202E DSO8102E DSO8072E Oscilloscope Source CH1 ~ CH2 Bandwidth 200MHz 100MHz 70MHz Sample Rate Range 1GS/s Peak Detect High-frequency and randon glith capture Waveform Interpolation (sin x)/x Record Length 2M Math , -, *, /, FFT Bandwidth Limit 20MHz Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Modes Auto, Normal, Single Rise Time at BNC (typical) 1.8ns 3.5ns 5ns Waveform Generator Mode Frequency Range 1Hz (DC)~25MHz Amplitude ±3.5V Max. Output Impedance 50 Ω Output Current 50mA  DMM Mode Max. Resolution 6000 Counts DMM Testing Modes Voltage, Current, Resistance, Capacitance, Diode & Continuity Input Impedance 10MΩ Max. Input Voltage AC:600V, DC:800V
Digital Ossilloscope Multimeter

Digital Ossilloscope Multimeter

  • Siglent SHS810 Handheld Digital Ossilloscope Meter 100Mhz
    $33.56 $50
  • UNI-T UT81B Ossilloscope Multimeter
    $13.4 $19.83
  • TOOLTOP ET2010A 2 in 1 True RMS Handheld Oscilloscope Multimeter
    $27.83 $35.9
  • HANTEK DSO1062B 60MHZ Digital Oscilloscope Multimeter
    $21.51 $38.72
  • CEM DT-9989 Digital Ossilloscope Digital Multimeter NCV True RMS
    $14.37 $26.01
  • UNI-T UTD1202C 200MHZ Handheld Digital Ossilloscope Meter
    $19.58 $36.03
  • Hantek DSO1202bv Digital Ossilloscope Multi Meter
    $26.58 $52.1
  • UNI-T UT81A Digital Oscilloscope Multimeter
    $26.34 $32.66
  • HANTEK DSO1202B Digital Ossilloscope Multimeter 200Mhz
    $31.48 $43.13
  • UNI-T UTD1025DL Digital Oscilloscope 25 Mhz
    $14.44 $18.19
  • UNI-T UTD1102C 100MHZ Handheld Digital Ossilloscope Meter
    $31.12 $51.97
  • Hantek DSO8102E 100Mhz Handheld Digital Ossilloscope Meter
    $23.86 $39.61
  • Siglent SHS806 Handheld Digital Ossilloscope Meter 60Mhz
    $21.48 $33.29
  • UNI-T UTD1025CL Ossilloscope Multimeter 25MHz
    $27.1 $34.15
  • UNI-T UT81C Multimeter Scope
    $28.72 $47.68
  • Oscilloscope JINHAN JDS2023 l 20Mhz
    $16.86 $24.45

© 2026 - MICHAELKORSPASCHER.FR